Toroid Transformers 230V, 2xSec, 15-1000VA, General Information
High quality open style toroidal transformers with a single 230V a.c., 50/60Hz primary winding.
Twin secondary windings may be connected in series, parallel or used independently.
- Small size and low weight compared with traditional stacked lamination types
- Extremely low level of radiated magnetic field
- Very low induced noise (hum)
- Very low iron loss
- Supplied with mounting kit
- 100% electrical and flash tested
- High quality manufacturing and testing in accordance to:
EN61558, EN60742, EN60950, EN60065, VDE0551, VDE0550 and BS415
- Tested and Approved by KEMA to EN61558
- UL Recognised to UL506
|
|
|
Rated VA |
Part Number
(xxx=Sec voltage) |
Regulation
% Typical |
Temperature Rise [K] |
Dimensions*
Diameter [mm] |
Height [mm] |
Weight [Kg] |
15 |
0015P1-2-xxx |
16 |
26 |
60 |
31 |
0.30 |
30 |
0030P1-2-xxx |
18 |
40 |
70 |
32 |
0.45 |
50 |
0050P1-2-xxx |
14 |
42 |
80 |
33 |
0.65 |
80 |
0080P1-2-xxx |
14 |
53 |
93 |
38 |
0.90 |
120 |
0120P1-2-xxx |
10 |
52 |
93 |
46 |
1.20 |
160 |
0160P1-2-xxx |
9 |
55 |
105 |
42 |
1.50 |
225 |
0225P1-2-xxx |
8 |
60 |
112 |
47 |
1.90 |
300 |
0300P1-2-xxx |
8 |
60 |
115 |
58 |
2.30 |
500 |
0500P1-2-xxx |
6 |
68 |
136 |
60 |
3.50 |
625 |
0625P1-2-xxx |
5 |
67 |
136 |
68 |
4.30 |
800 |
0800P1-2-xxx |
5 |
69 |
162 |
60 |
5.10 |
1000 |
1000P1-2-xxx |
5 |
72 |
162 |
70 |
6.50 |
- * Allow extra 4mm for mounting kit, allow extra 5mm where leads emerge
- Leads: PVC insulated 150mm long
- Secondary voltage tolerance <1% at nominal input
- UL recognised for Insulation Class A (105°C)
- Maximum ambient operating temperature +40°C
- Neoprene pads: 5kV isolation
- Meets all requirements of Class E (120°C)
Important Installation Note
Each transformer is supplied with a dished washer and protection pads for single hole fixing. Ensure that the pads are fitted above and below the transformer winding and that the dished washer is on top of the upper pad. Do not over tighten the fixing bolt (not supplied) as this could damage the winding.
Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame as this would create a "shorted turn" causing irreparable damage.
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|