AEP1000 -Centillium Chipsets
Features
- complies with ANSI and ETSI requirements
- matched to Centillium CT-L21SC08, CT-L41SC04, CT-L50SC04, CT-L50ST81 & CR-L-10AT01-H chipsets
- very low THD
- 1,500V minimum isolation
- all materials approved to UL-94V-0
- excellent quality at competitive price due to high volume production
- manufactured in ISO-9001 approved facility
|
|
|
Electrical Specifications @ 25°C
Operating Temperature: -40° to +85°C
Part
Number |
Package |
IC Driver |
Turns
Ratio
±2%
Line : IC |
LP
(µH) |
LL
(µH)
Max. |
CWW
(pF)
Max. |
DCR
(Ohms)
Max.
Line : IC |
THD
(Linearity)
Typical |
Longitudinal
Balance
Min. |
Insertion
Loss
Max. |
Frequency
Response
Max. |
Isolation
Voltage
(Vrms) |
AEP1000-T |
TH |
CT-L21SC08 CO
CT-L41SC04 CO |
1 : 1 |
462
±10% |
5 |
60 |
1,30 / 1,30 |
-67dB
10kHz |
-50dB
10kHz-1,1MHz |
0,5dB
100kHz |
1,0dB
30kHz-1,1MHz |
1.500 |
AEP1000-S |
SMD |
AEP1010-T |
TH |
CT-L50SC04 CO/CPE
CT-L50ST81 CO/CPE |
1,8 : 1 |
462
±10% |
10 |
70 |
1,30 / 0,90 |
-67dB
10kHz |
-50dB
10kHz-1,1MHz |
0,5dB
100kHz |
1,0dB
30kHz-1,1MHz |
AEP1010-S |
SMD |
AEP1020-S |
SMD |
CT-L10AT01-1T |
1 : 1.1 |
364
±5% |
11 |
60 |
2,10 / 2,20 |
-67dB
10kHz |
-45dB
20kHz-1,1MHz |
1,5dB
50kHz |
1,0dB
40kHz-1,1MHz |
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|