Electrical Specifications @ 25°C   Turns Ratio: Bold = IC side winding


ISM Series DIL Modules comply with Supplementary Insulation Level EN60950, UL 1950 and UL 1459

Part Number LP
(mH Min.)
Turns
Ratio 
LL
(µH Max.)
^IDC
(mA)
CC
(pF Max.)
RCUP
(Ohms)
RCUS
(Ohms)
VP
(Vrms)
Schematic
 ISM-100C1-XXX
 ISM-120A1-XXX
30
30
1/1:1/1
1/1:4
10
10
5
5
150
150
1.7
1.7
2.0
4.0
1,500
1,500
C1