ISJ -Mini Interface Transformer
Features
- designed for optimum compatibility with all established interface IC´s
- excellent and consistent balance between windings
- miniature surface mount package
- complies fully with CCITT.I.430 recommendations and corresponding national standardsfor S-lnterface
- manufactured in ISO-9001.2000 approved facility
- operating temperature: 0° to +70°C
|
|
|
|
|
Electrical Specifications @ 25°C |
|
Standard Packaging: Tape and Reel |
Surface Mount SO Interface Transformers
Part Number |
LN
(mH Min.) |
Turns
Ratio |
LL
(µH Max.) |
CC
(pF Max.) |
RCUP
(Ohms) |
RCUS
(Ohms) |
VP
(Vrms) |
ISJ-100B |
25 |
1:1 |
2.0 |
60 |
3.8 |
3.8 |
1,500 |
ISJ-140B |
25 |
1:2 |
2.0 |
50 |
4 |
8 |
1,500 |
Test Conditions |
|
|
Inductance (Lo): |
|
Line Side Windings in series - measurement @ 10kHz, 100mV |
Polarity and Turns Ratio: |
|
Pins 1-2:3-4:5-6:7-8=±2% |
Coupling Capacitance: |
|
IC side winding (windings in series) to Line side windings in series @ 10kHz, 100mV |
Leakage Inductance: |
|
Line side windings in series, IC side windings short circuited - measurement @ 100kHz, 100mV |
Test Voltage: |
|
1.5kV for 2 Sec. - Line side windings in series to IC side windings in series |
Coplanarity: |
|
±0.004(0.10mm) |
Dimensions
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|