AS Series Current Sensors - HF 20-200kHz
AS Series Current Sensors are designed as a low cost method of controlling, monitoring or measuring AC currents. The sensors serve as feedback elements between the output and pulse control circuitry providing accurate regulation of switch mode power supplies.
AS-100 Series
AS-200/300 Series
AS-400 Series
Features
- Fully encapsulated for optimal PC board mounting
- Frequency range from 20kHz to 200kHz
- Primary current rating to 15 Amps
- Primary to secondary isolated to 2500 VAC
- UL 94-V0 recognized materials
- Optimum performance over designated current and frequency range
- Competitive pricing due to high volume production
- Manufactured in ISO-9000 approved facility
|
|
|
Applications
Isolated current feedback signal in Switch Mode Power Supplies - Motor current load/overload - Lighting Switch Controls Ultra-sound current - High resolution sonar current - Isolated bi-directional current sensor with full wave bridge rectifier.
AS-100 Series
Electrical Specifications at 25°C
Inductor Part Number |
Prim/Sec Ratio |
Lsec (1)
(mH Min) |
DCRsec Ohms (Max) |
Sec Term (2) Resistance Ohms (Nom.) |
Isec (3) Max |
Vols-µS (4) Max |
Schematic |
AS-100
AS-101
AS-102
AS-103
AS-104
AS-105 |
1/50
1/100
1/200
1/300
1/500
1/750 |
6
25
100
250
700
1,682 |
0.6
1.1
4.5
10.0
25.0
43.0 |
50
100
200
300
500
750 |
300mA
150mA
75mA
50mA
30mA
40mA |
175
350
700
900
1,500
3,750 |
|
AS-110
AS-111
AS-112
AS-113
AS-114
AS-115 |
1/50CT
1/100CT
1/200CT
1/300CT
1/500CT
1/750CT |
6
25
100
250
700
1,682 |
0.3/0.3
0.55/0.55
2.25/2.25
5.0/5.0
12.5/12.5
21.5/21.5 |
25+25
50+50
100+100
150+150
250+250
375+375 |
300mA
150mA
75mA
50mA
30mA
40mA |
175
350
700
900
1,500
3,750 |
|
Notes:
1) Lsec: Secondary inductance tested at 10kHz and 10mV for 1:50 through 1:500.
Prim./Sec. ratios and 1kHz/10mV for Prim./Sec. ratio of 1:750
2) This nominal termination resistance value will yield approximately 1.0V of output for each amp of current in a single turn sense line. The output Voltage/Ampere of these devices can be increased or decreased linearly over a restricted temperature range by adjusting the terminating resistance.
3) For Prim./Sec. Ratios of 1:50 through 1:500, the Isec value corresponds to a maximum primary current of 15 Amp-turns rms while the Isec values for the ratio of 1:750 corresponds to a max. primary current of 30 Amp-turns rms
4) VµS = Rt x ls x (1/2F)
Rt (Ohms): Recommended Terminating Resistance
Is (A): Secondary Current
F (Hz): Frequency
5) Operating Temperature Range: -40°C to +120°C
6) Pin 2 is on Centre-Tapped (CT) versions only |
|
|
AS-200/300 Series
Electrical Specifications at 25°
Type 1 |
Type 2 |
Prim./Sec.
Ratio |
Lsec (1)
(mH Min.) |
DCRsec
Ohms (Max) |
Sec. Term (2)
Resistance
Ohms (Nom.) |
Isec (3)
Max. |
Volt-µS (4)
Max. |
Schedule |
AS-200
AS-201
AS-202 |
AS-300
AS-301
AS-302 |
1/50
1/100
1/200 |
5
20
80 |
0.65
1.30
4.50 |
50
100
200 |
300mA
150mA
75mA |
175
350
700 |
|
AS-210
AS-211
AS-212 |
AS-310
AS-311
AS-312 |
1/50
1/100
1/200 |
5
20
80 |
0.65
1.30
4.50 |
25+25
50+50
100+100 |
300mA
150mA
75mA |
175
350
700 |
|
|
AS-320
AS-321
AS-322 |
1/50
1/100
1/200 |
5
20
80 |
0.65
1.30
4.50 |
50
100
200 |
300mA
150mA
75mA |
175
350
700 |
|
|
AS-330
AS-331
AS-332 |
1/50CT
1/100CT
1/200CT |
5
20
80 |
0.65
1.30
4.50 |
25+25
50+50
100+100 |
300mA
150mA
75mA |
175
350
700 |
|
AS-400 Series
Features:
- Meets requirements of IEC 950 and VDE norms
- UL 94-V0 recognized materials
- Operating frequency range from 20 kHz to 200 kHz
- Operating Temperature Range: -40 °C to +120 °C
- Primary to secondary isolated to 4000 VAC
- Primary current rating to 80 Amps
Electrical Specifications at 25°C
Part
Number |
Prim./Sec
Ratio |
Ip A |
Volt-µS
(4)
Max. |
Application |
Schedule |
Box Type |
Dimensions |
C |
D |
E |
F |
G |
H |
I |
Hole |
AS-400
AS-401
AS-402 |
1/100
1/100
1/100 |
1
2
5 |
350
550
1,500 |
Switching
Switching
Switching |
|
A
A
B |
17.8
23.0
32.5 |
12.8
15.5
18.0 |
20.0
25.0
35.5 |
10.0
12.5
15.0 |
5.0
10.0
12.5 |
15.0
20.0
- |
5.0
5.0
- |
-
-
- |
AS-403 |
1/100 |
10 |
1,500 |
Switching |
|
A |
32.5 |
18.0 |
35.5 |
15.0 |
12.5 |
- |
- |
- |
AS-404
AS-405
AS-406
AS-407 |
1/100
1/500
1/500
1/500 |
50
50
65
80 |
1,500
2,700
4,200
7.500 |
Switching
Switching
Switching
Switching |
|
B
A
A
B |
32.5
23.0
27.0
32.5 |
18.0
15.5
18.0
18.0 |
35.5
25.0
30.0
35.5 |
15.0
12.5
15.0
15.0 |
12.5
10.0
12.5
12.5 |
-
20.0
22.5
- |
-
5.0
5.0
- |
Ø 8
Ø 6
Ø 8
Ø 8 |
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|